105 lines
2.9 KiB
Nix
105 lines
2.9 KiB
Nix
{ config, lib, pkgs, ... }:
|
|
|
|
with lib;
|
|
|
|
let
|
|
|
|
cfg = config.services.thinkfan;
|
|
configFile = pkgs.writeText "thinkfan.conf" ''
|
|
# ATTENTION: There is only very basic sanity checking on the configuration.
|
|
# That means you can set your temperature limits as insane as you like. You
|
|
# can do anything stupid, e.g. turn off your fan when your CPU reaches 70°C.
|
|
#
|
|
# That's why this program is called THINKfan: You gotta think for yourself.
|
|
#
|
|
######################################################################
|
|
#
|
|
# IBM/Lenovo Thinkpads (thinkpad_acpi, /proc/acpi/ibm)
|
|
# ====================================================
|
|
#
|
|
# IMPORTANT:
|
|
#
|
|
# To keep your HD from overheating, you have to specify a correction value for
|
|
# the sensor that has the HD's temperature. You need to do this because
|
|
# thinkfan uses only the highest temperature it can find in the system, and
|
|
# that'll most likely never be your HD, as most HDs are already out of spec
|
|
# when they reach 55 °C.
|
|
# Correction values are applied from left to right in the same order as the
|
|
# temperatures are read from the file.
|
|
#
|
|
# For example:
|
|
# sensor /proc/acpi/ibm/thermal (0, 0, 10)
|
|
# will add a fixed value of 10 °C the 3rd value read from that file. Check out
|
|
# http://www.thinkwiki.org/wiki/Thermal_Sensors to find out how much you may
|
|
# want to add to certain temperatures.
|
|
|
|
# Syntax:
|
|
# (LEVEL, LOW, HIGH)
|
|
# LEVEL is the fan level to use (0-7 with thinkpad_acpi)
|
|
# LOW is the temperature at which to step down to the previous level
|
|
# HIGH is the temperature at which to step up to the next level
|
|
# All numbers are integers.
|
|
#
|
|
|
|
sensor ${cfg.sensor} (0, 10, 15, 2, 10, 5, 0, 3, 0, 3)
|
|
|
|
${cfg.levels}
|
|
'';
|
|
|
|
in {
|
|
|
|
options = {
|
|
|
|
services.thinkfan = {
|
|
|
|
enable = mkOption {
|
|
default = false;
|
|
description = ''
|
|
Whether to enable thinkfan, fan controller for IBM/Lenovo ThinkPads.
|
|
'';
|
|
};
|
|
|
|
sensor = mkOption {
|
|
default = "/proc/acpi/ibm/thermal";
|
|
description =''
|
|
Sensor used by thinkfan
|
|
'';
|
|
};
|
|
|
|
levels = mkOption {
|
|
default = ''
|
|
(0, 0, 55)
|
|
(1, 48, 60)
|
|
(2, 50, 61)
|
|
(3, 52, 63)
|
|
(6, 56, 65)
|
|
(7, 60, 85)
|
|
(127, 80, 32767)
|
|
'';
|
|
description =''
|
|
Sensor used by thinkfan
|
|
'';
|
|
};
|
|
|
|
|
|
};
|
|
|
|
};
|
|
|
|
config = mkIf cfg.enable {
|
|
|
|
environment.systemPackages = [ pkgs.thinkfan ];
|
|
|
|
systemd.services.thinkfan = {
|
|
description = "Thinkfan";
|
|
after = [ "basic.target" ];
|
|
wantedBy = [ "multi-user.target" ];
|
|
path = [ pkgs.thinkfan ];
|
|
serviceConfig.ExecStart = "${pkgs.thinkfan}/bin/thinkfan -n -c ${configFile}";
|
|
};
|
|
|
|
boot.extraModprobeConfig = "options thinkpad_acpi experimental=1 fan_control=1";
|
|
|
|
};
|
|
|
|
}
|