2e751c0772
the conversion procedure is simple: - find all things that look like options, ie calls to either `mkOption` or `lib.mkOption` that take an attrset. remember the attrset as the option - for all options, find a `description` attribute who's value is not a call to `mdDoc` or `lib.mdDoc` - textually convert the entire value of the attribute to MD with a few simple regexes (the set from mdize-module.sh) - if the change produced a change in the manual output, discard - if the change kept the manual unchanged, add some text to the description to make sure we've actually found an option. if the manual changes this time, keep the converted description this procedure converts 80% of nixos options to markdown. around 2000 options remain to be inspected, but most of those fail the "does not change the manual output check": currently the MD conversion process does not faithfully convert docbook tags like <code> and <package>, so any option using such tags will not be converted at all.
100 lines
2.6 KiB
Nix
100 lines
2.6 KiB
Nix
{ config, lib, pkgs, ... }:
|
|
let
|
|
inherit (lib) mkEnableOption mkIf mkOption types;
|
|
|
|
cfg = config.hardware.sata.timeout;
|
|
|
|
buildRule = d:
|
|
lib.concatStringsSep ", " [
|
|
''ACTION=="add"''
|
|
''SUBSYSTEM=="block"''
|
|
''ENV{ID_${lib.toUpper d.idBy}}=="${d.name}"''
|
|
''TAG+="systemd"''
|
|
''ENV{SYSTEMD_WANTS}="${unitName d}"''
|
|
];
|
|
|
|
devicePath = device:
|
|
"/dev/disk/by-${device.idBy}/${device.name}";
|
|
|
|
unitName = device:
|
|
"sata-timeout-${lib.strings.sanitizeDerivationName device.name}";
|
|
|
|
startScript =
|
|
pkgs.writeShellScript "sata-timeout.sh" ''
|
|
set -eEuo pipefail
|
|
|
|
device="$1"
|
|
|
|
${pkgs.smartmontools}/bin/smartctl \
|
|
-l scterc,${toString cfg.deciSeconds},${toString cfg.deciSeconds} \
|
|
--quietmode errorsonly \
|
|
"$device"
|
|
'';
|
|
|
|
in
|
|
{
|
|
meta.maintainers = with lib.maintainers; [ peterhoeg ];
|
|
|
|
options.hardware.sata.timeout = {
|
|
enable = mkEnableOption "SATA drive timeouts";
|
|
|
|
deciSeconds = mkOption {
|
|
example = 70;
|
|
type = types.int;
|
|
description = lib.mdDoc ''
|
|
Set SCT Error Recovery Control timeout in deciseconds for use in RAID configurations.
|
|
|
|
Values are as follows:
|
|
0 = disable SCT ERT
|
|
70 = default in consumer drives (7 seconds)
|
|
|
|
Maximum is disk dependant but probably 60 seconds.
|
|
'';
|
|
};
|
|
|
|
drives = mkOption {
|
|
description = lib.mdDoc "List of drives for which to configure the timeout.";
|
|
type = types.listOf
|
|
(types.submodule {
|
|
options = {
|
|
name = mkOption {
|
|
description = lib.mdDoc "Drive name without the full path.";
|
|
type = types.str;
|
|
};
|
|
|
|
idBy = mkOption {
|
|
description = lib.mdDoc "The method to identify the drive.";
|
|
type = types.enum [ "path" "wwn" ];
|
|
default = "path";
|
|
};
|
|
};
|
|
});
|
|
};
|
|
};
|
|
|
|
config = mkIf cfg.enable {
|
|
services.udev.extraRules = lib.concatMapStringsSep "\n" buildRule cfg.drives;
|
|
|
|
systemd.services = lib.listToAttrs (map
|
|
(e:
|
|
lib.nameValuePair (unitName e) {
|
|
description = "SATA timeout for ${e.name}";
|
|
wantedBy = [ "sata-timeout.target" ];
|
|
serviceConfig = {
|
|
Type = "oneshot";
|
|
ExecStart = "${startScript} '${devicePath e}'";
|
|
PrivateTmp = true;
|
|
PrivateNetwork = true;
|
|
ProtectHome = "tmpfs";
|
|
ProtectSystem = "strict";
|
|
};
|
|
}
|
|
)
|
|
cfg.drives);
|
|
|
|
systemd.targets.sata-timeout = {
|
|
description = "SATA timeout";
|
|
wantedBy = [ "multi-user.target" ];
|
|
};
|
|
};
|
|
}
|